+380673912731
Your region — Соединенные Штаты Америки?

One-touch turn signal module

One-touch turn signal module

Turns extenders designed for easering maneuvering and overtaking the transpositions, evev in the city and highway. You will not have to be distracted by turns off the maneuvers as arm bends enough to enable one-touch turns to further their automatic shut-off. Feel comfortable behind the wheel!

Выберите марку автомобиля
Выберите модель автомобиля
Ваше устройство:

Ваша схема:

ЗАПРОС НА ПОИСК
Обратите особое внимание на правильность введенной информации.
Ввод неверной или неполной информации не позволит нам найти нужную схему на автомобиль.
Если у вас уже есть схема - то отправьте ее нам. Этим вы существенно ускорите процесс поиска!


read more...


Лидер продаж!
One Touch Turn Signal LC-1.4H
One Touch Turn Signal LC-1.4H
Выберите марку автомобиля Выберите модель автомобиля ..
12 -16 V not more than 5 mA 7 А -40°C +50°C 1 to 8
$18.00
Лидер продаж!
One Touch Turn Signal  LC-1.4L
One Touch Turn Signal LC-1.4L
Выберите марку автомобиля Выберите модель автомобиля Ваше..
12 -16 V not more than 5 mA 7 А -40°C +50°C 1 to 8
$18.00
Лидер продаж!
Onу Touch Turn Signal  LC-1.6
Onу Touch Turn Signal LC-1.6
Выберите марку автомобиля Выберите модель автомобиля ..
12 -16 V not more than 5 mA to 100mA -40°C +50°C configurable*
$18.00
One-touch turn signal module LC-1.8H
Выберите марку автомобиля Выберите модель автомобиля Ваше..
12 -16 V not more than 5 mA 7 А -40°C +50°C 1 to 8
$18.00
Set LC-1.4H + DM-2.3A
Buy a set of devices to share, it is cheaper !!! OTTS module LC-1.4H together with autodimmer ..
$30.00
Showing 1 to 5 of 5 (1 Pages)

FAQ

FAQ Удлинители поворотов

One touch turn module

1) Extenders turns LC-1.6 programmed as follows:
- correctly connect the device according to the scheme;
- turn on the power to the device, from this moment begins the countdown (10 seconds), after which, entering the programming mode will be impossible;
- Include a right turn onto two blinks, then turn left turn onto two blinks. ;
- The device will confirm entry in programming mode by blinking right turn and then a left turn;
- Programming number of blinks turns elongational: Turn right turn down to the number of flashes and turn it off.
2) LC-1.4H modules and LC-1.4L programmed as follows:
- correctly connect the device according to the scheme;
- turn on the power to the unit and within 5 seconds after the force the 3 flashing left turn, left turn switch off, turn on the 3 flashing right turn, stop turn right - the device will blink twice alarms in acknowledgment of entering the programming mode;
- turn left turn and count the number of the desired extension turns, turn off left turn;
- turn right turn and count the number of blinks desired function "thank you" to turn off the turn, the device flashes twice in acknowledgment exit programming.

1) Check the insertion of the device according to the diagram in, and visually verify that you have connected (Did you accidentally hooked it up mirror)
2) Check if the power is fed to the device (excellent helps tester)
3) Do not confuse recheck whether power polarity (+ and -)
4) Check the system voltage (should be between 12-14,5 V)
5) If all of the above does not work, find EXPLANATORY (required) electrician and give him instructions, machines, and can ... money, maybe help
6) call us :-(
1) Immediately turn it off. Improper connection of the device (Believe me, checked it 100%) If left on, it will burn.
2) Recheck the insertion device of diagram in, and visually verify that you have connected (Did you accidentally hooked it vice versa)
3) Recheck the correct connection of the orange and blue wires
4) If all of the above does not work, find EXPLANATORY (required) electrician and give him instructions, machines, and can ... money, maybe help
5) call us :-( And if suddenly burned, then send to us for repair.
Modules differ in several characteristics, namely:
1) For power applications (all versions LC-1.4 и LC-1.8)
2) For low-voltage circuits (LC-1.6)
3) Polarity alarm management, while reversing
- controlled positive polarity (LC-1.4H и LC-1.8)
- controlled negative polarity (LC-1.4L)
4) In a work schedule
- from the nominal relay LC-1.4H, LC-1.4L (clicks when working corners, or alarm)
- Interval time LC-1.6, LC-1.8 (major peaks in turns during operation, or alarm)
Gray wire without terminals needed for triggering an alarm when the vehicle is reversing.
In the module version LC-1.4H it responds to the positive polarity (+),
In the module version LC-1.4L it responds only to the negative polarity (-)
In the module version LC-1.6 it responds to the positive polarity (+)

User connection One-touch turn signal module, go to the instruction manual, in the liner. If you can not find the fate that we will put into the device, or we put her provtykal you see below.
Instruction One-touch turn signal module LC-1.4H

Instruction One-touch turn signal module LC-1.4L
Instruction One-touch turn signal module LC-1.6

CONNECTION One-touch turn signal module, go to the instruction manual, in the liner (if you choose when you order the make and model of car) or on our website to each device tab used in cars". If you have lost the instructions that came in the kit, see item like a wiring diagram
What would just pick up the device production CAR CHIPS on your car, or find a scheme, it is sufficient to just use a special filter and select your make and model of car, seen in the video how to do it. If not your circuit, then ask us a question here
Также менять реле поворотов. Смотри пункт "При незаведенном двигателе удлинитель поворотов LC-1.4 работает, а при заведенном нет".
Менять реле поворотов на такое, недорогое, широко распространенное, а главное - проверенное
замена реле поворотов
либо дорабатываете родное - необходимо допаять всего один резистор
Заменить реле поворотов. Смотри пункт "При незаведённом двигателе удлинитель поворотов LC-1.4 работает, а при заведённом нет"